• End user :
    • Clerk
  • Customer :
    • Esteem India Pvt. Ltd.
  • Boiler capacity :
    • 0.50 MK cal.
  • Application :
    • For generation of medium or low pr steam.
  • Role :
    • Designing of complete GT Set
  • Purpose :
    • recover heat from exhaust gases for improvement of eff.
  • Sources :
    • Exhaust of gas turbine wrking on NG, Naptha
  • Exhaust gas temp :
    • 520 to 450 deg based on GT design and fuel.
    • can be cooled to 140 deg c
  • Design :
    • Natural circulation or force circulation
    • With or without extended surfaces
    • With or without duct burner for additional heat
    • Combination of MP + LP steam
    • Horizontal, vertcal configuration.
    • Precaution against steaming in econmser due to poor pinch and approch

Technologies